Tank Fill. Note: After the tank fill process is complete, the display will not show the same amount as the programmed fill level. The display shows the amount of refrigerant that is available for charging, which is approximately 0. Welcome to ManualMachine. We have sent a verification link to to complete your registration. Log In Sign Up. Forgot password? Enter your email address and check your inbox. Please check your email for further instructions. Enter a new password. Table of Contents Safety Precautions.
Control Panel Functions. Setup Menu Functions. Install Oil Drain Bottle. Power Up the Machine. Register the Machine. Calibration Check. Replace Oxygen Sensor in Refrigerant Identifier. Change Vacuum Pump Oil. AC Rev. Safety Precautions Explanation of Safety Signal Words Used in this Manual The safety signal word designates the degree, or level, of hazard seriousness.
Do not use in open air in case of rain or high humidity. Wear gloves. Wear protection goggles. Alternating voltage. Grounding protection. Electrical shock hazard. Before operating the machine, read and follow the instructions and warnings in this manual. The operator must be familiar with air conditioning and refrigeration systems, refrigerants, and the dangers of pressurized components.
Ensure the phase has been completed before disconnecting the machine to prevent the release of refrigeration to the atmosphere.
Some mixtures of air and refrigerant have been shown to be combustible at elevated pressures. Technical Specifications Compressor. Backlight Adjusts the contrast on the display screen. Calibration Check Use to verify internal scale calibration. Change Vacuum Pump Oil Displays how long the vacuum pump has operated since the last oil change, and the amount of time remaining until the next oil change is needed.
Date and Time Setup Program the machine for current date and time. Default Charge Target Change the default charge amount that appears on the charge programming screen.
Filter Change The filter removes acid, particulates, and moisture from the refrigerant. To meet requirements, it is mandatory to replace the filter after kg lbs. Garage Data Programs information that will appear on the printout each time the print function is used.
Hose Flush Flushes residual oil from the machine to prepare for the service of next vehicle. Language Selection Select a language for screen prompts. Refrigerant Management Displays the amount of refrigerant recovered, charged, and replenished for the life of the machine , and filtered since the last filter change.
Service For Robinair service center use only. System Information Displays the revision level of the software in the machine. Unit of Measure Program the machine to display units of measure in kilograms or pounds. Setup Unpack the Accessory Kit Unpack the accessory kit from the box, and remove the plastic packaging.
Install Oil Drain Bottle 1. Oil Drain Bottle Figure 1. Power Up the Machine 1. Lock the front wheels. Register the Machine When the Product Activation screen appears on the display, follow on-screen prompts to register the machine. Enter your user name and password, and log in to the website. Enter the activation code into the field on the AC display and press OK.. The Product Activation Key will be displayed in this field. Language Selection The operator selects the language for the screen prompt displays.
The license agreement is displayed for your approval, after which the machine continues with SETUP mode. Unit of Measure The operator sets the display for units of measure. Metric is the default.
Date and Time Setup The machine is programmed at the factory for the local time zone, using a hr. Note: The date changes only by scrolling through an entire day. Press OK to accept the date and time. Service Installation Clearing At this point the machine clears its internal plumbing before proceeding with setup.
Open the service couplers. The machine displays 4. Tank Filling The internal storage vessel ISV maximum fill of new refrigerant may be adjusted between 1.
Maximum recovery is 9. Strap Tank Fill Hose Figure 3 Note: After the tank fill process is complete, the display will not show the same amount as the programmed fill level. You can only view or download manuals with. Sign Up and get 5 for free. Upload your files to the site. You get 1 for each file you add. Get 1 for every time someone downloads your manual. Buy as many as you need. Flow Diagram Wiring Diagram Limited Warranty Patents: 4,,; 4,, Re 33,; 4,,; 4,,; 4,,; 4,,; 4,,; 5,,; 5,,; 5,,; 5,,; 5,,; 5,,; Australian Patent: ,; Canadian Patents: 1,,; 1,,; 2,,; 2,,; European Patent: 0 Bl; German Patent: Mexican Patent: OTHER U.
This manual contains important safety procedures concerning the operation, use, and maintenance of this product. Failure to follow the instructions contained in this manual may result in serious injury. If you are unable to understand any of the contents of this manual, please bring it to the attention of your supervisor.
Do not operate this equipment unless you have read and understood the contents of this manual. The K models are used for Ra vehicles, whereas the K models are used for R vehicles.
Both models are designed to be compatible with existing service equipment and standard service procedures. To validate your warranty, complete the warranty card attached to your unit, and return it within ten days from date of purchase. Internal Storage Vessel The refillable refrigerant storage vessel designed. In addition to the number keys, the keypad contains special keys that accomplish specific operating functions. Ra systems have special fittings per SAE specifications to avoid cross-contamination with R systems.
Do not attempt to adapt your unit for another refrigerant — system failure will result! Read and follow all warnings at the beginning of this manual before operating the unit. Avoid the use of an extension cord, because the extension cord may overheat.
However, if you must use an extension cord, use a No. The first time the unit is powered up, it will start in the initial setup mode. If the initial setup must be performed again, it may be selected using the menu function.
The first step is to select a language. Next select the operating units. NOTE: The vacuum pump is shipped without oil in the reservoir. Before starting the pump, oil must be added to the pump, or damage to the pump may occur.
Attach the flexible tube and cap to the oil bottle, and pour eight ounces of vacuum pump oil into the fill port. While the vacuum pump is running, slowly add oil until the level rises to the center of the reservoir's sight glass.
Press the STOP key, and replace the black plastic plug on the fill port. Connect the fill hose to a full source tank. Open the tank valve. Invert the tank and install it on the back of the unit, making sure to secure the tank strap. NOTE : If using a refillable tank, install the tank upside down, and connect the fill hose to the vapor valve. The unit stops when a sufficient amount of refrigerant has been transferred to the internal tank, or when the source tank is empty.
Press the STOP key to pause the process. This process takes minutes. NOTE: Add at least 8 lb. When the fill process is complete, you may press STOP to exit. The unit is now ready to operate. NOTE: There is no need to calibrate the scale, because it is calibrated at the factory. Press the MENU button. The menu choices are:. The filter-drier removes acid, particulates, and water from the refrigerant. Change the filter-drier after pounds 68 kg of refrigerant has been filtered.
Press the MENU key. To pause recycling, press the STOP key. Connect the fill hose to the source tank. Invert the tank, install it on the back of the unit, and secure the tank strap. The unit stops when a sufficient amount of refrigerant has been transferred to the internal tank, or if the source tank is empty.
When the fill process is complete, press STOP to exit. This function displays how long the vacuum pump has run since the last oil change. See page 20 of this manual for details. Press STOP to exit. This function is used to show the operator how many pounds or kilograms of refrigerant have been recovered since the last filter change. These mixtures are potentially dangerous and may result in fire or explosion causing personal injury or property damage. Additional health and safety information may be obtained from refrigerant and lubricant manufacturers.
Glossary of Terms Operating Tips Using The Control Panel Component Location and Identification Set-Up Instructions Installing the Tank Setting up the Unit Adding Refrigerant to the Unit Tank Operating Instructions Recovering Refrigerant Air Purge Maintenance Instructions Checking and Calibrating the Scale Replacing the Filter-Drier Checking and Resetting Filter Capacity Checking for Leaks Choosing the Temperature Scale Troubleshooting Tips Vacuum Flow Diagram Recover Flow Diagram Charge Flow Diagram Replacement Parts Limited Warranty This manual contains important safety procedures concerning the operation, use and maintenance of this product.
Failure to follow the instructions contained in this manual may result in serious injury.
0コメント